Fitting the hood body
Open the doors (See section Open Panels).
Remove the Metal grease filters using the handles
provided.
Adjust the two screws Vr, in the brackets 11a, so that
they are at the start of their travel.
Hook the hood body to the two brackets 11a.
From the inside of the hood body, turn screws Vr to
level the hood body itself.
Fasten the safety screw 11.
Close the doors again.
Vr
11a
11
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid pipe ø 150
or 120 mm, the choice of which is left to the installer.
To install a ø 120 mm air exhaust connection, insert
the reducer flange 9 on the hood body outlet.
Fix the pipe in position using sufficient pipe clamps
(not supplied).
Remove possible charcoal filters.
ø 150
9
ø 120
Vista de página 16